K10 long-burning wood boiler
  • Model: L10
  • Shipping Weight: 280 kg

€2,299.00

K10 long-burning wood boiler – a new type of wood boiler

  • The effortless and reliable long-burning wood boiler suits backup, emergency and main heating systems; for heating a storage tank, buffer tank or radiator network, for permanent and occasional use.
  • Excellent especially when a large storage tank or buffer tank cannot be used.
  • The boiler's whole large chamber is filled with wood, and the stack burns in a controlled way from top to bottom.
  • Max output 10 kW
  • CE mark
  • The boiler is tested and certified to EN 303-5:2012 and meets class 5.
  • The boiler is made to ISO 9001 and ISO 14001 standards.
  • Efficiency up to 86%.
  • Dimensions: D 580mm x H 1700mm
  • Recommended for buildings under 100 m2 
    The boiler's features are second to none: 
    1. Efficiency 86% 
    2. Heats up quickly and runs unattended for a long time 
    3. Self-regulating without electronics or electricity 
    4. Extremely reliable 
    5. Designed to connect to modern heating systems 
    6. Low fuel use and burns many kinds of fuel 
    7. Completely silent 
    8. Easy to maintain 

    The way the boiler works is ingenious! 
    The long-burning wood boiler is a top-combustion boiler in which the fire moves from top to bottom. The boiler has 2 steel cylinders forming a 20 mm water jacket + an insulated outer casing. At the top of the cylinder is the supply air valve, followed directly by the air heating chamber. The upper door is for loading and lighting the wood. The lower door is for ash removal. 
    Heated supply air flows through the telescopic pipe into the fire. The fire moves downwards and always gets heated supply air through the telescopic pipe, which moves down with the fire. 

    A heat exchanger of this shape is the best possible – all the heat goes into the water. 
    The wood boiler is filled once; no wood may be added during the burn. The burn lasts 12–24 hours (36 hours with briquettes) depending on the heat demand. The boiler does not burn wood needlessly, only as needed. This matters when choosing a boiler – the bigger the boiler, the less often it is loaded. 

    The supply air valve adjusts the combustion air according to the boiler water temperature – as the temperature nears the set value, the valve reduces the air; when it exceeds the set value, the valve shuts off the air and the boiler starts to cool. The supply air stops in the heating chamber and gets hot, because the combustion air below it is still hot. Without fire the boiler water cools quickly and the supply air valve opens. The hot supply air easily blows the embers back into flame. 
    In practice the valve rarely closes completely; the control reacts sensitively to heat consumption – e.g. hot water use makes the boiler raise its output almost immediately. The whole process runs by itself, thanks to the boiler's ingenious idea. 

    A power cut is not dangerous for this boiler if the pipes are large enough – the heating system can run by gravity.

    Tank use

    In a heating system, the long-burning boiler behaves much like an oil or pellet boiler, because the burn adapts to the heat demand – so a large buffer tank is not needed. A buffer tank still improves efficiency; the recommendation is 20 l per kW of output. A cost-effective way is to combine the buffer tank and the hot water tank in one – a buffer tank with a hot water coil or a heat exchanger package. The boiler works naturally with the tank: it keeps the tank temperature up, and when the temperature drops below the set value, the boiler raises it again for as long as the wood lasts. This also gives you hot water in summer without electricity. 
    The long-burning boiler was developed in Lithuania over 15 years ago. The boiler type is CE approved. We have supplied long-burning wood boilers to our customers in Finland since 2010, and all owners have been happy with this ingenious solution. The K10 long-burning wood boiler is safe and easy to look after. It can be installed in new and old houses, and as part of hybrid heating.

    Supply air fan.

    In a long-burning boiler a fan can be used in problem situations such as poor draught or damp wood. The fan should always be used when the chimney draught is poor or the burn needs more air. 
    Example: you burn wood with more moisture than expected. Wetter wood needs more air to burn, so the fan helps in this case. Note! In normal use the fan is not switched on. 

    Technical data: 

     

  • Efficiency 86%
  • Recommended boiler water temperature 70C
  • Water volume 30l
  • Boiler water flow – 400 l/hour
  • Firewood capacity 35kg
  • Firewood length max 45cm
  • Flue connection D 160mm, 1370 mm from the floor
  • Piping 1"
  • Fuel: logs and various fuel briquettes, 
    The wood boiler is approved and certified (Cert No 0662/0288/05) for use on a concrete floor without a base. If the boiler room has no concrete floor, or the floor is e.g. tiled, a concrete base is available as an option. 
     
  • The boiler is a safe choice when you want to be sure the radiators are warm in the morning too. 

    in the diagram: 
    1. Fan 
    2. Air valve 
    3. Air inlet 
    4. Control valve for the air intake valve 
    5. Flow connection 
    6. Air heating chamber 
    7. Flue connection 
    8. Lifting cable for the air supply distributor 
    9. (wood/coal) changeover handle 
    10. Fuel loading doors 
    11. Air distributor 
    12. Firewood 
    13. Hook for the lifting cable 
    14. Ash removal door 
    15. Grate (option) 
    16. Grate support 
    17. Return connection 
    18. Air intake pipe (telescopic pipe) 
    19. Safety valve