Attack SLX 40-55 Profi / Lambda wood gasifying boiler

(image for) Attack SLX 40-55 Profi / Lambda wood gasifying boiler
Attack SLX 40-55 Profi / Lambda wood gasifying boiler
(image for) Attack SLX 40-55 Profi / Lambda wood gasifying boiler
Attack SLX 40-55 Profi / Lambda wood gasifying boiler
(image for) Attack SLX 40-55 Profi / Lambda wood gasifying boiler
Attack SLX 40-55 Profi / Lambda wood gasifying boiler
(image for) Attack SLX 40-55 Profi / Lambda wood gasifying boiler
Attack SLX 40-55 Profi / Lambda wood gasifying boiler
  • Model: SLX 55
  • Shipping Weight: 1050 kg
  • Manufactured by: Attack - (SK) Slovakia

Starting at: €6,924.00

Please Choose:

A. control





Power







down-draught boiler, wood gasification

  • The flue gases are burned in the gas combustion chamber with double supply air
  • Large volume
  • Economical firewood consumption
  • Easy cleaning
  • Long logs
  • Fast ignition with the fan 

    Overnight burn function. Up to 8-12 hours of burn time with a full fuel chamber! 
    Efficiency: 92%
    Voltage/frequency 230/50 V/Hz
    noise: 65 dB
     

    Storage tanks, circulation pumps and other accessories – profil.fi


    Thanks to its combustion efficiency, the bottom-combustion (down-draught) boiler is the best type of solid fuel boiler. The fuel is loaded through the front door into a large fuel chamber. The large chamber makes heating much easier thanks to the long burn time. Clean combustion at high temperature reduces fuel consumption and the need to clean the boiler. Once adjusted, the boiler is economical to run. 
    In bottom-combustion boilers the fuel burns in two stages. Clean combustion is based on a correctly shaped secondary combustion chamber lined with ceramic bricks and on preheated secondary air. 

    ATTACK is CE certified. CE certificate 1015

  • In bottom combustion the wood is gasified, which produces tar and acids. To prevent this, and for better operation and boiler life, a boiler water mixing valve must be installed so that the water temperature is 65C, e.g. the circulation pump group Regumat Oventrop or Laddomat. 

     
  • The boiler must run continuously at over 50% of its output.
  • The boiler's ecological operating output is its nominal output.
  • We recommend a buffer tank, which saves 20-30% fuel, extends the life of the boiler and chimney and makes heating easier. If a large buffer tank is not possible, we recommend at least a small one – 25 l per 1 kW of boiler output. 
     
  • The boiler is a safe choice when you want to be sure the wood is burned efficiently and all its heat value goes to the heating system. The boiler is strong and reliably made.

Copyright © 2026 Kotituli.fi. Contact and self-collection